FatalErrors.info
Search by Model
or by Error Code
Search
Error code: 142F
<- Back
Description :
Circulation pump motor lock error.
Explanation :
There is something wrong with connection of the circulation pump motor.
The circulation pump motor was driving at an abnormally slow speed.
Overload.
Failure of the circulation pump motor encoder.
Failure of the circulation pump motor.
Check points :
Is there any disconnected connectors or damaged cables in the connection between the circulation pump motor and the Main Board?
Does the circulation pump motor encoder scan normally?
Remedy :
Replace the Circulation Pump Unit.