Error code: 14A8
<- Back
Description :
Pump motor 1 overcurrent error
Causes :
Connection failure of the motor or the encoder. The number of occurrences of overcurrent to the motor has reached a predetermined limit.
Irregular load.
Encoder failure.
Motor failure.
Remedy :
Replace the pump cap unit (Full).