FatalErrors.info
Search by Model
or by Error Code
Search
Error code: 14AB
<- Back
Description :
Pump motor 1 over speed error
Causes :
The motor was driven at a speed faster than a predetermined one during deceleration.
Irregular load.
Encoder failure.
Motor driver failure.
Remedy :
Replace the pump cap unit (Full).
Replace the main board.