Error code: 141A
<- Back
Description :
Pump motor overload error
Explanation :
Overcurrent to the Pump Motor was detected.
Pump Motor encoder cable disconnection.
Pump Motor cable disconnection.
Irregular load.
Pump Motor encoder failure.
Pump Motor failure.
Check points :
Is there any problems such as damaged cable in the pump motor (pump motor encoder) to main board connection?
Does the Pump Motor encoder work properly?
Remedy :
Replace the Pump Motor encoder and Pump Motor (Pump Cap Unit).