Error code: 00010006

<- Back

CR motor overcurrent error.

Explanation:
During CR Motor operation, there may be a case where an abnormal current out of the specified limits is detected in the CR Motor drive circuit on the C472MAIN Board or a current exceeding the specified value is required. In such a case, this message is displayed and the printer stops operating.

Cause of trouble:
Hardware has detected overcurrent in the CR motor circuit.

Points to be checked:
1. Measure the resistance value of the CR Motor (5.8 Ohm). If the CR Motor is found in short mode, replace the C472MAIN Board at the same time.
2. By visual inspection, check the T Fence for any defect, such as damage or soiling, which can cause faulty reading by the sensor.
3. By visual inspection, check the harness of the CR Motor for any problem causing a short circuit to the frame.

Remedy:
1. Replace the MAIN Board (C472 MAIN)
2. Replace the CR Motor ASSY.
3. Correct the carriage home position.
4. Remove the foreign matters. Clean the timing fence.