FatalErrors.info
Search by Model
or by Error Code
Search
Error code: 122B
<- Back
Description :
PF motor over speed error
Explanation and causes :
Detects that it is being driven at an irregularly faster speed than the specified value just before stopping.
Irregular load.
Encoder failure.
Check points and solutions :
Replace the PF Encoder Sensor.